fix: correct CPU and memory slot deduplication on HP ProLiant
- discovery.cpp: remove K_SERIAL emission from dmidecode CPU "ID" field
(it is the CPUID instruction result, identical across matching processors
in a multi-socket system, not a unique per-slot serial number)
→ upsert_part now falls through to K_SOCKET natural key, correctly
inserting both "Proc 1" and "Proc 2" as separate records
- discovery.cpp: skip memory slot blocks with missing or empty Locator
(HP ProLiant firmware returns a phantom type-17 block with no Locator;
this was causing a 19th slot record to be inserted with empty locator
that could never be deduplicated on subsequent runs)
Verified on HP ProLiant DL360 G7:
cpu=2, cpu_slots=2, memory_sticks=12, memory_slots=18, disks=5, nics=4
Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
This commit is contained in:
parent
b9736266c9
commit
7a8ea3e88f
2 changed files with 6 additions and 2 deletions
BIN
orchestration/ansible/roles/inventory-cli/files/inventory-cli
Executable file
BIN
orchestration/ansible/roles/inventory-cli/files/inventory-cli
Executable file
Binary file not shown.
|
|
@ -486,6 +486,9 @@ std::vector<DiscoveredPart> Discovery::discover_memory_slots() {
|
||||||
}
|
}
|
||||||
|
|
||||||
for (auto& b : blocks17) {
|
for (auto& b : blocks17) {
|
||||||
|
// Skip blocks without a Locator — these are malformed/phantom HP firmware entries
|
||||||
|
if (!b.count("Locator") || b["Locator"].empty()) continue;
|
||||||
|
|
||||||
DiscoveredPart p;
|
DiscoveredPart p;
|
||||||
p.type_name = PTYPE_MEMORY_SLOT;
|
p.type_name = PTYPE_MEMORY_SLOT;
|
||||||
|
|
||||||
|
|
@ -579,8 +582,9 @@ std::vector<DiscoveredPart> Discovery::discover_cpus() {
|
||||||
DiscoveredPart p;
|
DiscoveredPart p;
|
||||||
p.type_name = PTYPE_CPU;
|
p.type_name = PTYPE_CPU;
|
||||||
|
|
||||||
if (b.count("ID") && b["ID"] != "Not Specified")
|
// Do NOT use dmidecode "ID" (CPUID family/model/stepping) as serial —
|
||||||
p.kv[K_SERIAL] = b["ID"];
|
// it is identical across matching CPUs in multi-socket systems.
|
||||||
|
// Socket designation is the actual unique natural key.
|
||||||
if (b.count("Version") && b["Version"] != "Not Specified")
|
if (b.count("Version") && b["Version"] != "Not Specified")
|
||||||
p.kv[K_NAME] = b["Version"];
|
p.kv[K_NAME] = b["Version"];
|
||||||
if (b.count("Manufacturer") && b["Manufacturer"] != "Not Specified")
|
if (b.count("Manufacturer") && b["Manufacturer"] != "Not Specified")
|
||||||
|
|
|
||||||
Loading…